WanderTherm — Comprehensive Product Spec

Product family: WanderTherm (smart thermostat, round wall-mount, 4 tiers: Core, Plus, Pro, Lux) Category: Indoor climate control / smart thermostat Supersedes: local-LLM draft /tmp/draft-wandertherm-DECISIONS.md (validated 94/100; refined to canonical 2-tier per scope) Revision: v1.0-candidate (SOP v2.4 artifact-complete) Status: designed, not built; nothing ordered and no firmware written yet Ideation source: WanderVerse master plan + sibling families (WanderAir HVAC adjacency, planned sensor pucks) + hero render wandertherm-hero-2026-04-24.png Date: 2026-04-24 (hardware sections updated 2026-10-21)

---

Product render: canonical hero

The hero render shows the earlier April concept. The current v1 design is:

---

One-paragraph review brief

WanderTherm is a planned smart thermostat in four tiers (Core, Plus, Pro, Lux) designed to replace Nest 4th Gen ($279) while delivering a meaningfully better experience: zero cloud required, covert mode + duress code (survivor / undocumented / hostile-state aware), identity-aware defaults, a planned later 24 V module for wired HVAC systems (not in v1), 7-year parts + open STL face plates + published schematics, AHRI 1380 + Energy Star Connected for utility rebate eligibility, Matter 1.3+ over WiFi + HomeKit + Google Home + Alexa + Home Assistant first-class, decision-tree schedule learning that explains itself (NOT opaque ML), Ambassador-assembled, 60/30/10 Community Pool. Every tier is designed around the same core: a Seeed XIAO ESP32-S3 brain, a Bourns PEC11R turning ring, a 4-pin JST I2C bay for plug-in modules, and USB-C 5 V power from a Phihong AQ15A-050B-H wall adapter. v1 talks to Home Assistant over Wi-Fi, which runs the ACs; it has no HVAC wires, no relays, no mains voltage, no battery and no sensors in the wall unit. Screens by tier: Core a small round color screen, Plus NHD-2.8, Pro NHD-3.12, Lux NHD-5.5. Pro and Lux add 24 GHz mmWave presence, off by default. All tiers feed the 60/30/10 Community Pool. Comparable competitors require cloud accounts, paywall geofencing, ship microphones in thermostats, and have no identity-aware defaults at all.

---

Product tiers

TierDevice IDRetailFoundingNonprofitStatus
**Core**TBDTBDTBDTBDdesigned, not built
**Plus**TBDTBDTBDTBDdesigned, not built
**Pro**`WV-THERM-PRO`TBDTBDTBDdesigned, not built
**Lux**TBDTBDTBDTBDdesigned, not built

Nonprofit pricing requires Mission Partner / 501(c)(3) verification (HAVEN safehouses, trans clinics, DV shelters, Title-I schools, weatherization-program-eligible households).

---

Positioning

Headline: "Your home's climate. Your data. No cloud. No subscription. No outing."

Sub-headlines:

Target audiences:

---

Core functional features

All tiers (shared core)

Thermostat function:

FeatureImplementation
Wired 24V HVAC controlNot in v1: no HVAC wires, no relays, no mains voltage. v1 sends commands over Wi-Fi to Home Assistant, which runs the ACs. Planned later: a v4 24 V module with 5 triacs (not relays) for central, heat-only and heat-pump systems; it needs a design review first
OpenTherm support (EU)Not in v1. Would depend on the planned later 24 V module
Heat / cool / auto modesMatter `Thermostat` cluster compliant
Programmable schedule7-day + 4-events-per-day + override
Decision-tree schedule learningLocal CART algorithm + 14-day Bayesian confidence; user-interpretable; user-lockable rules
GeofencingPhone-app local geofence (no cloud); arrival/departure setbacks
Setback / setpoint holdVacation hold + manual hold + smart-hold-during-occupancy
Outdoor temperatureLocal NWS API or HA-provided sensor
Filter-change reminderTime-based (90/180/365 day options); cross-product with WanderAir HVAC Monitor for actual Δp-based reminder

Sensing:

MetricSensorRangeAccuracy
Room temperatureNone in the wall unit in v1; uses room sensors already in the home, through Home AssistantDepends on the room sensorDepends on the room sensor
Relative humiditySame as aboveDepends on the room sensorDepends on the room sensor
Own sensor puck (planned v2)Temperature + humidity puck; parts not chosen yetTBDTBD

Display + UI:

Connectivity:

Power:

Identity-aware features:

Pro and Lux tiers, plus planned later modules

Multi-zone HVAC control (planned later, not v1):

FeatureImplementation
Zone controlNot in v1. Would depend on the planned v4 24 V module (5 triacs, not relays), which needs a design review first
Zoned-heating algorithmPID per zone + occupancy-fused setback, planned for when zone hardware exists

External sensors (all tiers):

FeatureImplementation
Room sensorsv1 reads sensors already in the home through Home Assistant
Own sensor pucksPlanned v2: temperature + humidity puck; parts not chosen yet
Door/window-open detectionCross-product with Sensor Pod Door Mini; pauses heating in open-window rooms

Local presence:

FeatureImplementation
Seeed 24 GHz mmWave (101010001), Pro and Lux onlyIdentity-free presence detection at thermostat location; off by default, the owner opts in
Occupancy-aware setbackWhen presence is turned on, learns occupancy patterns and sets back when no one is home

---

Differentiators vs Nest / ecobee / Honeywell / tado°

AxisWanderThermNest 4th Genecobee PremiumHoneywell T6 Protado° X
Retail (entry / flagship)**TBD**$279$189 / $249$199$249
Subscription**$0 forever**$0 (currently)$0 (Eco+ data-share)$0€25/yr Auto-Assist
Cloud required❌ local-first🔴 Google account🔴 ecobee account🟡 hybrid🔴 tado° cloud
Covert mode✅ unique❌❌❌❌
Duress code✅ unique❌❌❌❌
Identity-aware defaults✅ unique❌❌❌❌
HAVEN safehouse preset✅ unique❌❌❌❌
OpenTherm + 24V single SKU🟡 planned later module❌ 24V only❌ 24V only🟡 separate SKUs✅ OT-first
Matter 1.3+ over WiFi🟡 planned, not built🟡 Google Home bridge✅ native🟡 Resideo bridge🟡 2026 update
HomeKit native🟡 planned, not built❌✅❌❌
Home Assistant native✅ ESPHome upstream🟡 community🟡 community🟡 community🟡 community
Decision-tree learning (interpretable)✅❌ opaque ML🟡 rule-based❌❌
External sensors🟡 via Home Assistant; own pucks planned (v2)✅ 18 max✅ 32 max✅ 20 max✅
Built-in mic / speaker❌ deliberate❌✅ Premium❌❌
7-year parts + firmware✅🟡 14-yr 1st gen🟡 5-yr❌ 1-yr🟡 2-yr
Open STL face plates✅ CC-BY-SA❌❌❌❌
Published schematics✅❌❌❌❌
Ambassador-assembled✅❌❌❌❌
AHRI 1380 cert🟡 not tested (planned)✅✅✅🟡
Energy Star Connected✅✅✅✅✅
Utility Demand Response (OpenADR 2.0b)✅✅✅🟡❌
60/30/10 Community Pool✅❌❌❌❌

Result: These are design targets for a product that isn’t built yet. No axis has been tested against these thermostats.

---

Dual-mode architecture

Mode 1: Standalone (zero other WanderVerse purchases)

Mode 2: Industry-integrated (Matter + HomeKit + Google + Alexa + HA)

Mode 3: WanderVerse-native (with WanderNode Hub + other WV products)

---

Identity-aware / safety-aware defaults

This is a WanderVerse-unique feature. Defaults adapt respectfully to user-declared identity without forcing disclosure.

User-declared contextAdjusted default
**DV survivor / abuser-pattern household**Covert mode armed; duress code configured; admin-only WiFi config; no cloud sync prompt; no Matter advert outside local subnet
**Undocumented household**Generic SSID; no telemetry; Spanish/Portuguese/Mandarin/Vietnamese GUIDE; no LE-search-warrant-discoverable cloud account
**Trans / LGBTQ+ in hostile state**No telemetry; ambient-only app mode; no notifications visible on lock screen; covert mode available
**Pediatric in household**Quiet turning-ring operation; minimum/maximum setpoint guards (prevent kid setting to 90°F)
**Pregnant**Tighter humidity range (40-55%); cross-product alerts for HCHO via WanderAir
**HRT / post-op recovery**Tighter temperature stability (±0.5 °C deadband vs default ±1 °C)
**Chronic illness (ME/CFS, MCAS, Long COVID)**Cross-product mold-indicator alerts (humidity from room sensors + VOC pattern from WanderAir)
**HAVEN safehouse**Multi-occupant mode; admin-only config; covert mode auto-arm on factory reset; staff + resident dashboard separation
**Climate-event-affected household**Auto-fan-only ventilation modes for wildfire smoke event (cross-product with WanderAir geofence)
**Utility rebate participant**OpenADR 2.0b Demand Response opt-in toggle in setup

All declared via WanderVerse Profile: optional, revocable, local-only storage. Never sent to a cloud. Never sold. Never used in adtech.

---

WanderVerse Community Pool integration

Per WANDERVERSE-COMMUNITY-POOL-SPEC.md:

Per-unit Community Pool amounts depend on a retail price, which is not set.

---

7-year commitment

Per Standards 2, 4, 6b:

Consumables NOT in 7-year:

---

Ambassador assembly

Per Standard 1:

---

Key strategic role

WanderTherm is the WanderVerse HVAC anchor:

---

Open implementation items

Not booked or scheduled. Planned before any unit is sold: 1. UL 60730-1 + UL 60730-2-9 cert lab booking (Intertek or UL Northbrook) 2. AHRI 1380 smart thermostat performance test 3. OpenTherm interop EU trip (Vaillant / Viessmann / Worcester-Bosch / Junkers), only if the planned 24 V module is built 4. Display supply: a second source per tier for the 7-year spares promise, and the Core round screen part (unresolved), 2026-Q4 5. Decision-tree schedule learning model 14-day field validation, 2027-Q2 6. v4 24 V module design review, including its high-voltage regulator (not chosen yet) 7. Matter Thermostat cluster CSA cert 8. Energy Star Connected Thermostat v1.0 application 9. Contract manufacturer PCBA + chassis + Ambassador assembly, 2026-Q4 10. Covert mode firmware audit (SSID + mDNS + Matter suppression), 2027-Q2 11. Duress code → WanderNode Hub integration spec, 2027-Q2 12. v2 sensor puck parts (not chosen yet) 13. HAVEN deployment field guide + Ambassador on-site training, 2027-Q4 14. ESPHome upstream wandertherm component PR, 2026-Q4 15. EU CE EN 60730 + OpenTherm cert (planned 24 V module, if built), 2027-Q3 16. 24V isolation hipot fixture (1500 VAC per UL 60730-1 §H.27), for the planned 24 V module 17. Industrial-design hire (face plate + bezel + saffron pinstripe finish QC). UL 60730 and AHRI 1380 matter once the planned 24 V module controls a furnace or heat pump. For the USB-C v1, the first gate is FCC certification of the radio.